{"id":13930,"date":"2022-06-16T12:00:39","date_gmt":"2022-06-16T10:00:39","guid":{"rendered":"https:\/\/www.sfen.org\/?post_type=article-rgn&p=13930"},"modified":"2022-06-17T09:42:34","modified_gmt":"2022-06-17T07:42:34","slug":"les-emissions-carbone-du-nucleaire-francais-37g-de-co2-le-kwh","status":"publish","type":"article-rgn","link":"https:\/\/www.sfen.org\/rgn\/les-emissions-carbone-du-nucleaire-francais-37g-de-co2-le-kwh\/","title":{"rendered":"Les \u00e9missions carbone du nucl\u00e9aire fran\u00e7ais\u00a0: 4g de CO2 le kWh"},"excerpt":{"rendered":"","protected":false},"template":"","tag-rgn":[693,957,368,853],"rgn-category":[260],"rgn-report-category":[],"acf":{"category":[{"term_id":260,"name":"EN DIRECT","slug":"en-direct","term_group":0,"term_taxonomy_id":260,"taxonomy":"rgn-category","description":"","parent":0,"count":1716,"filter":"raw"}],"rgn_article_report":false,"folder":false,"rgn_article_type":"public","sfen_image":{"ID":13923,"id":13923,"title":"Int\u00e9gration du CNPE de Saint-Laurent-des-Eaux dans son environnement","filename":"EDF-BEAUCARDET-WILLIAM-PWP-scaled.jpg","filesize":520371,"url":"https:\/\/www.sfen.org\/wp-content\/uploads\/2022\/06\/EDF-BEAUCARDET-WILLIAM-PWP-scaled.jpg","link":"https:\/\/www.sfen.org\/rgn\/les-emissions-carbone-du-nucleaire-francais-37g-de-co2-le-kwh\/attachment\/integration-du-cnpe-de-saint-laurent-des-eaux-dans-son-environnement-2\/","alt":"","author":"14","description":"","caption":"Vue du CNPE de Saint Laurent des Eaux dans son environnement.","name":"integration-du-cnpe-de-saint-laurent-des-eaux-dans-son-environnement-2","status":"inherit","uploaded_to":13930,"date":"2022-06-15 13:50:17","modified":"2022-06-15 16:32:50","menu_order":0,"mime_type":"image\/jpeg","type":"image","subtype":"jpeg","icon":"https:\/\/www.sfen.org\/wp-includes\/images\/media\/default.png","width":2560,"height":1261,"sizes":{"thumbnail":"https:\/\/www.sfen.org\/wp-content\/uploads\/2022\/06\/EDF-BEAUCARDET-WILLIAM-PWP-150x150.jpg","thumbnail-width":150,"thumbnail-height":150,"medium":"https:\/\/www.sfen.org\/wp-content\/uploads\/2022\/06\/EDF-BEAUCARDET-WILLIAM-PWP-300x148.jpg","medium-width":300,"medium-height":148,"medium_large":"https:\/\/www.sfen.org\/wp-content\/uploads\/2022\/06\/EDF-BEAUCARDET-WILLIAM-PWP-768x378.jpg","medium_large-width":768,"medium_large-height":378,"large":"https:\/\/www.sfen.org\/wp-content\/uploads\/2022\/06\/EDF-BEAUCARDET-WILLIAM-PWP-1024x505.jpg","large-width":1024,"large-height":505,"1536x1536":"https:\/\/www.sfen.org\/wp-content\/uploads\/2022\/06\/EDF-BEAUCARDET-WILLIAM-PWP-1536x757.jpg","1536x1536-width":1536,"1536x1536-height":757,"2048x2048":"https:\/\/www.sfen.org\/wp-content\/uploads\/2022\/06\/EDF-BEAUCARDET-WILLIAM-PWP-2048x1009.jpg","2048x2048-width":2048,"2048x2048-height":1009,"sfen-rgn-newsletter-featured":"https:\/\/www.sfen.org\/wp-content\/uploads\/2022\/06\/EDF-BEAUCARDET-WILLIAM-PWP-590x225.jpg","sfen-rgn-newsletter-featured-width":590,"sfen-rgn-newsletter-featured-height":225,"sfen-rgn-newsletter-ad":"https:\/\/www.sfen.org\/wp-content\/uploads\/2022\/06\/EDF-BEAUCARDET-WILLIAM-PWP-621x175.jpg","sfen-rgn-newsletter-ad-width":621,"sfen-rgn-newsletter-ad-height":175,"sfen-rgn-newsletter-article":"https:\/\/www.sfen.org\/wp-content\/uploads\/2022\/06\/EDF-BEAUCARDET-WILLIAM-PWP-325x285.jpg","sfen-rgn-newsletter-article-width":325,"sfen-rgn-newsletter-article-height":285,"sfen-rgn-newsletter-event":"https:\/\/www.sfen.org\/wp-content\/uploads\/2022\/06\/EDF-BEAUCARDET-WILLIAM-PWP-325x240.jpg","sfen-rgn-newsletter-event-width":325,"sfen-rgn-newsletter-event-height":240,"sfen-rgn-newsletter-cover":"https:\/\/www.sfen.org\/wp-content\/uploads\/2022\/06\/EDF-BEAUCARDET-WILLIAM-PWP-93x46.jpg","sfen-rgn-newsletter-cover-width":93,"sfen-rgn-newsletter-cover-height":46,"large_size":"https:\/\/www.sfen.org\/wp-content\/uploads\/2022\/06\/EDF-BEAUCARDET-WILLIAM-PWP-1280x631.jpg","large_size-width":1280,"large_size-height":631,"medium_size":"https:\/\/www.sfen.org\/wp-content\/uploads\/2022\/06\/EDF-BEAUCARDET-WILLIAM-PWP-410x202.jpg","medium_size-width":410,"medium_size-height":202}},"flexible_content":[{"acf_fc_layout":"text","text":"

Le 16 juin 2022, EDF a publi\u00e9 son analyse du cycle de vie du parc nucl\u00e9aire fran\u00e7ais. Conclusion, le kWh nucl\u00e9aire fran\u00e7ais \u00e9met moins de 4 g \u00e9quivalent CO2<\/sub>. Cette analyse d\u00e9taill\u00e9e va permettre d\u2019identifier les \u00e9tapes et les flux les plus contributeurs au bilan dans une optique d\u2019am\u00e9lioration, souligne EDF. C\u2019est \u00e9galement l\u2019occasion de clarifier les diff\u00e9rents chiffres parfois cit\u00e9s dans la vie d\u00e9mocratique de l\u2019Hexagone.<\/strong><\/p>\n

Dans la litt\u00e9rature scientifique, les \u00e9missions des diff\u00e9rentes \u00e9nergies peuvent varier selon la m\u00e9thodologie utilis\u00e9e ou le pays \u00e9tudi\u00e9. Le chiffre faisant r\u00e9f\u00e9rence pour le nucl\u00e9aire au niveau international est celui du Groupe d’experts intergouvernemental sur l’\u00e9volution du climat (Giec)[1]<\/a>\u00a0: 12 g \u00e9q. CO2\/kWh. Pour rappel, la m\u00e9diane est le chiffre qui s\u00e9pare un jeu de donn\u00e9e en deux parties \u00e9gales. N\u00e9anmoins, les m\u00e9thodes d\u2019extractions et d\u2019enrichissement de l\u2019uranium, l\u2019empreinte carbone des mat\u00e9riaux de construction ou encore la strat\u00e9gie de gestion des mati\u00e8res radioactives sont autant de facteurs pouvant faire varier \u2013 l\u00e9g\u00e8rement – les \u00e9missions carbone du kWh. En France, l’Agence de l’environnement et de la ma\u00eetrise de l’\u00e9nergie (Ademe) dans sa base[2]<\/a> estime les \u00e9missions du kWh nucl\u00e9aire \u00e0 6 g de CO2. \u00c0 titre de comparaison, les \u00e9missions des centrales \u00e0 gaz sont estim\u00e9es, toujours par l\u2019Ademe, \u00e0 418 g CO2 par kWh et celles des centrales \u00e0 charbon \u00e0 1058 g CO2 par kWh. Quant aux \u00e9nergies renouvelables, le kWh en France se situe autour de 10 g pour l\u2019\u00e9olien et de 30 g pour le solaire photovolta\u00efque. EDF, se basant sur les donn\u00e9es du parc en 2019, actualise, pr\u00e9cise et confirme le caract\u00e8re bas carbone du nucl\u00e9aire avec un kWh inf\u00e9rieur \u00e0 4 g de CO2<\/a>. Un exercice d’autant plus important qu’en France seulement 30 % des moins de 25 ans approuvent l’id\u00e9e que \u00ab\u00a0l’\u00e9nergie nucl\u00e9aire est un atout pour lutter contre le changement climatique\u00a0\u00bb contre 50 % des plus de 50 ans (source Barom\u00e8tre EDF).<\/p>\n

La m\u00e9thodologie r\u00e9pond \u00e0 un cahier des charges\u00a0: les normes ISO<\/strong><\/p>\n

L\u2019analyse du cycle de vie (ACV)<\/strong> est une m\u00e9thode normalis\u00e9e devant r\u00e9pondre aux exigences d\u2019ISO 14040-44. Elle repose sur l\u2019inventaire des flux de mati\u00e8re et d\u2019\u00e9nergie pour les diff\u00e9rentes phases du cycle de vie du produit, de l\u2019extraction des mati\u00e8res premi\u00e8res jusqu\u2019\u00e0 la gestion des d\u00e9chets. La cr\u00e9dibilit\u00e9 de l\u2019ACV est renforc\u00e9e par la revue critique d\u2019un comit\u00e9 d\u2019experts en accord avec la norme ISO\/TS 14071.<\/p>\n

Le champ de l\u2019\u00e9tude <\/strong>int\u00e8gre les donn\u00e9es du parc en 2019 soit 34 r\u00e9acteurs de 900 MW, dont 22 \u00ab\u00a0mox\u00e9s[3]<\/a>\u00a0\u00bb, 20 r\u00e9acteurs de 1 300 MW et 4 de 1 450 MW. L\u2019\u00e9tude ne prend pas en compte le transport de l\u2019\u00e9lectricit\u00e9.<\/p>\n

Au-del\u00e0 du CO2<\/strong>, les r\u00e9sultats de l\u2019analyse int\u00e8gre bien les diverses \u00e9missions que ce soit le m\u00e9thane (CH4), le protoxyde d\u2019azote (N2O), l\u2019hexafluorure de soufre (SF6), etc. C\u2019est ce qu\u2019exprime l\u2019indication \u00ab\u00a0grammes \u00e9quivalent<\/u> CO2 par kWh\u00a0\u00bb.<\/p>\n

P\u00e9rim\u00e8tre de l’analyse du cycle de vie (ACV), \u00a9EDF<\/u><\/p>\n

\"\"<\/p>\n

Les r\u00e9sultats de l\u2019\u00e9tude<\/strong><\/p>\n

D\u00e9tails des \u00e9missions de CO2 du parc nucl\u00e9aire fran\u00e7ais, <\/u>\u00a9<\/strong>EDF<\/u><\/p>\n

\"\"<\/p>\n

La r\u00e9partition des \u00e9missions du nucl\u00e9aire qui forment un total de 3,7 g \u00e9q. CO2 par kWh montre une importance particuli\u00e8re de l\u2019amont du cycle alors qu\u2019au contraire, la d\u00e9construction, la maintenance et le stockage des d\u00e9chets ont un poids n\u00e9gligeable.<\/p>\n

Les \u00e9tudes de sensibilit\u00e9 montrent qu\u2019une exploitation de 60 ans fait baisser l\u2019empreinte carbone de 8 % (3,4 g CO2\/kWh) par rapport \u00e0 une exploitation de 40 ans. L\u2019impact d\u2019une variation de 10 % de la production \u00e9lectrique annuelle par rapport \u00e0 2019 est de 0,1 g CO2\/kWh. EDF conclu que la sensibilit\u00e9 globale offre un spectre de 2,9 \u00e0 4,6 g eq CO2 \/kWh.<\/p>\n

Au-del\u00e0 des \u00e9missions de gaz \u00e0 effet de serre<\/strong><\/p>\n

L\u2019analyse s\u2019est int\u00e9ress\u00e9e \u00e0 diff\u00e9rents impacts environnementaux, la radioactivit\u00e9, l\u2019impact sur la sant\u00e9 humaine et sur les \u00e9cosyst\u00e8mes marins et terrestres, l\u2019empreinte au sol, l\u2019\u00e9puisement des ressources, etc. Pour en savoir plus, retrouvez l\u2019\u00e9tude sur le site EDF<\/a>. \u25a0<\/a><\/p>\n"}],"sfen_chapo":"

La r\u00e9daction Sfen – Cr\u00e9dit photo EDF-Beaucardet William\/PWP<\/strong><\/p>\n

[1]<\/a> https:\/\/www.ipcc.ch\/site\/assets\/uploads\/2018\/02\/ipcc_wg3_ar5_annex-iii.pdf<\/p>\n

[2]<\/a> https:\/\/bilans-ges.ademe.fr\/documentation\/UPLOAD_DOC_FR\/index.htm?conventionnel.htm<\/p>\n

[3]<\/a> R\u00e9acteurs utilisant du combustible compos\u00e9 d\u2019un m\u00e9lange d’oxydes issu du traitement du combustible us\u00e9.<\/p>\n","title_field":"Les \u00e9missions carbone du nucl\u00e9aire fran\u00e7ais : 4g de CO2 le kWh","content_teaser":"

Le 16 juin 2022, EDF a publi\u00e9 son analyse du cycle de vie du parc nucl\u00e9aire fran\u00e7ais. Conclusion, le kWh nucl\u00e9aire fran\u00e7ais \u00e9met moins de 4 g \u00e9quivalent CO2<\/sub>. Cette analyse d\u00e9taill\u00e9e va permettre d\u2019identifier les \u00e9tapes et les flux les plus contributeurs au bilan dans une optique d\u2019am\u00e9lioration, souligne EDF. C\u2019est \u00e9galement l\u2019occasion de clarifier les diff\u00e9rents chiffres parfois cit\u00e9s dans la vie d\u00e9mocratique de l\u2019Hexagone.<\/p>\n","rgn_subscriber_push_link_title":"","rgn_subscriber_push_link_url":""},"yoast_head":"\nLes \u00e9missions carbone du nucl\u00e9aire fran\u00e7ais\u00a0: 4g de CO2 le kWh - Sfen<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.sfen.org\/rgn\/les-emissions-carbone-du-nucleaire-francais-37g-de-co2-le-kwh\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Les \u00e9missions carbone du nucl\u00e9aire fran\u00e7ais\u00a0: 4g de CO2 le kWh - Sfen\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sfen.org\/rgn\/les-emissions-carbone-du-nucleaire-francais-37g-de-co2-le-kwh\/\" \/>\n<meta property=\"og:site_name\" content=\"Sfen\" \/>\n<meta property=\"article:modified_time\" content=\"2022-06-17T07:42:34+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"Les \u00e9missions carbone du nucl\u00e9aire fran\u00e7ais\u00a0: 4g de CO2 le kWh\" \/>\n<meta name=\"twitter:description\" content=\"Le 16 juin 2020, EDF a publi\u00e9 son analyse du cycle de vie du parc nucl\u00e9aire fran\u00e7ais. Conclusion, le kWh nucl\u00e9aire fran\u00e7ais \u00e9met moins de 4 g \u00e9quivalent CO2. Cette analyse d\u00e9taill\u00e9e va permettre d\u2019identifier les \u00e9tapes et les flux les plus contributeurs au bilan dans une optique d\u2019am\u00e9lioration, souligne EDF. C\u2019est \u00e9galement l\u2019occasion de clarifier les diff\u00e9rents chiffres parfois cit\u00e9s dans la vie d\u00e9mocratique de l\u2019Hexagone.\" \/>\n<meta name=\"twitter:image\" content=\"https:\/\/www.sfen.org\/wp-content\/uploads\/2022\/06\/EDF-BEAUCARDET-WILLIAM-PWP-scaled.jpg\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.sfen.org\/rgn\/les-emissions-carbone-du-nucleaire-francais-37g-de-co2-le-kwh\/\",\"url\":\"https:\/\/www.sfen.org\/rgn\/les-emissions-carbone-du-nucleaire-francais-37g-de-co2-le-kwh\/\",\"name\":\"Les \u00e9missions carbone du nucl\u00e9aire fran\u00e7ais\u00a0: 4g de CO2 le kWh - Sfen\",\"isPartOf\":{\"@id\":\"https:\/\/www.sfen.org\/#website\"},\"datePublished\":\"2022-06-16T10:00:39+00:00\",\"dateModified\":\"2022-06-17T07:42:34+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.sfen.org\/rgn\/les-emissions-carbone-du-nucleaire-francais-37g-de-co2-le-kwh\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.sfen.org\/rgn\/les-emissions-carbone-du-nucleaire-francais-37g-de-co2-le-kwh\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.sfen.org\/rgn\/les-emissions-carbone-du-nucleaire-francais-37g-de-co2-le-kwh\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.sfen.org\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Article RGN\",\"item\":\"https:\/\/www.sfen.org\/rgn\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Les \u00e9missions carbone du nucl\u00e9aire fran\u00e7ais\u00a0: 4g de CO2 le kWh\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.sfen.org\/#website\",\"url\":\"https:\/\/www.sfen.org\/\",\"name\":\"Sfen\",\"description\":\"Soci\u00e9t\u00e9 Fran\u00e7aise d'\u00c9nergie Nucl\u00e9aire\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.sfen.org\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Les \u00e9missions carbone du nucl\u00e9aire fran\u00e7ais\u00a0: 4g de CO2 le kWh - Sfen","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.sfen.org\/rgn\/les-emissions-carbone-du-nucleaire-francais-37g-de-co2-le-kwh\/","og_locale":"fr_FR","og_type":"article","og_title":"Les \u00e9missions carbone du nucl\u00e9aire fran\u00e7ais\u00a0: 4g de CO2 le kWh - Sfen","og_url":"https:\/\/www.sfen.org\/rgn\/les-emissions-carbone-du-nucleaire-francais-37g-de-co2-le-kwh\/","og_site_name":"Sfen","article_modified_time":"2022-06-17T07:42:34+00:00","twitter_card":"summary_large_image","twitter_title":"Les \u00e9missions carbone du nucl\u00e9aire fran\u00e7ais\u00a0: 4g de CO2 le kWh","twitter_description":"Le 16 juin 2020, EDF a publi\u00e9 son analyse du cycle de vie du parc nucl\u00e9aire fran\u00e7ais. Conclusion, le kWh nucl\u00e9aire fran\u00e7ais \u00e9met moins de 4 g \u00e9quivalent CO2. Cette analyse d\u00e9taill\u00e9e va permettre d\u2019identifier les \u00e9tapes et les flux les plus contributeurs au bilan dans une optique d\u2019am\u00e9lioration, souligne EDF. C\u2019est \u00e9galement l\u2019occasion de clarifier les diff\u00e9rents chiffres parfois cit\u00e9s dans la vie d\u00e9mocratique de l\u2019Hexagone.","twitter_image":"https:\/\/www.sfen.org\/wp-content\/uploads\/2022\/06\/EDF-BEAUCARDET-WILLIAM-PWP-scaled.jpg","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.sfen.org\/rgn\/les-emissions-carbone-du-nucleaire-francais-37g-de-co2-le-kwh\/","url":"https:\/\/www.sfen.org\/rgn\/les-emissions-carbone-du-nucleaire-francais-37g-de-co2-le-kwh\/","name":"Les \u00e9missions carbone du nucl\u00e9aire fran\u00e7ais\u00a0: 4g de CO2 le kWh - Sfen","isPartOf":{"@id":"https:\/\/www.sfen.org\/#website"},"datePublished":"2022-06-16T10:00:39+00:00","dateModified":"2022-06-17T07:42:34+00:00","breadcrumb":{"@id":"https:\/\/www.sfen.org\/rgn\/les-emissions-carbone-du-nucleaire-francais-37g-de-co2-le-kwh\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sfen.org\/rgn\/les-emissions-carbone-du-nucleaire-francais-37g-de-co2-le-kwh\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.sfen.org\/rgn\/les-emissions-carbone-du-nucleaire-francais-37g-de-co2-le-kwh\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.sfen.org\/"},{"@type":"ListItem","position":2,"name":"Article RGN","item":"https:\/\/www.sfen.org\/rgn\/"},{"@type":"ListItem","position":3,"name":"Les \u00e9missions carbone du nucl\u00e9aire fran\u00e7ais\u00a0: 4g de CO2 le kWh"}]},{"@type":"WebSite","@id":"https:\/\/www.sfen.org\/#website","url":"https:\/\/www.sfen.org\/","name":"Sfen","description":"Soci\u00e9t\u00e9 Fran\u00e7aise d'\u00c9nergie Nucl\u00e9aire","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sfen.org\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/www.sfen.org\/wp-json\/wp\/v2\/article-rgn\/13930"}],"collection":[{"href":"https:\/\/www.sfen.org\/wp-json\/wp\/v2\/article-rgn"}],"about":[{"href":"https:\/\/www.sfen.org\/wp-json\/wp\/v2\/types\/article-rgn"}],"wp:attachment":[{"href":"https:\/\/www.sfen.org\/wp-json\/wp\/v2\/media?parent=13930"}],"wp:term":[{"taxonomy":"tag-rgn","embeddable":true,"href":"https:\/\/www.sfen.org\/wp-json\/wp\/v2\/tag-rgn?post=13930"},{"taxonomy":"rgn-category","embeddable":true,"href":"https:\/\/www.sfen.org\/wp-json\/wp\/v2\/rgn-category?post=13930"},{"taxonomy":"rgn-report-category","embeddable":true,"href":"https:\/\/www.sfen.org\/wp-json\/wp\/v2\/rgn-report-category?post=13930"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}